Posted on

Comprehensive Analysis of the Yaskawa Varispeed F7 PG Feedback Card — A Practical Study on the SI-P1 Ver 3.04

1. Introduction: The Role of the PG Card in Inverter Control Systems

In modern vector-control inverters, the PG card (Pulse Generator card) plays a central role.
It acts as an interface between the inverter and the motor encoder, acquiring high-precision rotational signals from the motor shaft and feeding them back to the inverter’s control CPU.
Through this feedback, the inverter can precisely detect speed, position, and rotational phase, enabling closed-loop vector control, zero-servo holding, stable-speed regulation, and torque compensation.

In Yaskawa’s Varispeed F7 series, the PG feedback card is not just an accessory—it is the core component that transforms the inverter from a standard open-loop V/f device into a high-performance vector drive.
With accurate speed feedback, the F7 achieves servo-level control precision, excellent dynamic response, and high stability even under heavy load variations.

This paper focuses on the SI-P1 Ver 3.04 PG card (code 73600-C0333 / SIP-901), an OEM version widely used in the F7 family.
By comparing it with the official PG-A2/B2/D2/X2 cards described in Yaskawa’s manuals, we analyze its structure, compatibility, wiring method, parameter configuration, and field performance in real industrial applications.


2. Technical Background — Function and Principle of PG Feedback

2.1 Basic Function of the PG Card

The PG card’s primary function is to receive incremental encoder signals (A, B, Z phases) and convert them into the internal pulse format that the inverter’s CPU can process.
Based on these pulses, the inverter continuously calculates the rotational speed, direction, and position deviation of the motor.

This closed-loop feedback enables several advanced control modes:

  • Speed Feedback Control — maintains a precise target RPM regardless of load fluctuation.
  • Torque Compensation — improves low-speed torque stability.
  • Zero-Servo Control — holds the motor shaft at a fixed mechanical position.
  • Regenerative Braking Control — enhances braking torque using feedback phase information.

The accuracy and signal integrity of the PG card determine the overall response time, torque precision, and stability of the system.


2.2 Common PG Cards Used with the Varispeed F7

ModelSignal TypeSupply VoltageTypical ApplicationRemarks
PG-A2Differential TTL (A/A¯, B/B¯, Z/Z¯)+5 VStandard incremental encodersMost widely used type
PG-B2Open-collector (single-ended A/B)+12 VNPN output encodersFor environments with higher noise
PG-D2Push-pull (A/B/Z quadrature)+15 VHeavy industrial, long-distance feedbackExcellent noise immunity
PG-X2High-speed TTL differential+5 VHigh-resolution / high-speed vector controlUsed in advanced servo applications

All four cards share the same mechanical interface and CN5 connector, but differ in electrical levels and signal types.
Among them, PG-A2 is the standard type used in most F7 applications.


3. Identifying the SI-P1 Ver 3.04 and Its Compatibility

Although the SI-P1 Ver 3.04 is not explicitly listed in the official F7 manual, practical testing and circuit comparison confirm that:

The SI-P1 Ver 3.04 is an OEM-equivalent version of the PG-A2 card.

The justification is as follows:

  1. Identical Signal Architecture
    The SI-P1 accepts differential inputs for A, /A, B, /B, Z, /Z, which perfectly matches the TTL line-driver interface of PG-A2.
  2. Same Power Requirements
    It provides an internal +5 V DC output (maximum 200 mA) for encoder supply—exactly like the PG-A2—and does not support 12 V or 15 V encoders.
  3. Same Physical Connector
    The card plugs directly into the F7 control PCB via the CN5 slot. Pin layout and dimensions are identical to the PG-A2.
  4. Firmware Generation
    The “Ver 3.04” label corresponds to the firmware generation period of early-2000s Yaskawa F7 inverters, when PG-A2 was the default model.

Hence, the SI-P1 card can be treated as functionally identical to PG-A2.
All wiring, parameter settings, and diagnostic methods described for PG-A2 apply equally to SI-P1.


4. Detailed Wiring between the SI-P1 and the Encoder

4.1 Terminal Definitions

PinSignal NameFunctionDescription
1+5 VEncoder Power SupplyProvides +5 V DC (≤ 200 mA)
20 VPower GroundCommon reference for encoder
3APhase A positiveForward rotation signal
4/APhase A negativeDifferential complement
5BPhase B positive90° shift from A
6/BPhase B negativeDifferential complement
7ZZero-mark signalOnce-per-revolution pulse
8/ZZero-mark complementOptional connection
FGFrame GroundConnect to shield of cable

Use twisted-pair shielded cable for each differential pair (A/A¯, B/B¯, Z/Z¯).
Connect the cable shield to FG at the inverter side only.


4.2 Typical Wiring Diagram

Encoder Side               SI-P1 PG Card
+5 V  ───────────────────────→  Pin 1 (+5 V)
0 V   ───────────────────────→  Pin 2 (0 V)
A    ───────────────────────→  Pin 3 (A)
A¯   ───────────────────────→  Pin 4 (/A)
B    ───────────────────────→  Pin 5 (B)
B¯   ───────────────────────→  Pin 6 (/B)
Z    ───────────────────────→  Pin 7 (Z)
Z¯   ───────────────────────→  Pin 8 (/Z)
Shield layer ─────────────→  FG (Ground)

This standard differential connection ensures noise immunity and reliable high-speed feedback, even under strong EMI conditions.


4.3 Electrical Precautions

  • Keep the encoder cable shorter than 20 m; for longer runs, use a differential line driver (RS-422 standard).
  • Never connect both ends of the shield to ground—do so only on the inverter side.
  • Verify the A/B phase shift (90° ± 10°) using an oscilloscope; reversed A/B causes inverted rotation detection.
  • Avoid running encoder cables in parallel with power cables.

5. Parameter Configuration and Commissioning

To enable the feedback loop, several parameters must be configured in the Varispeed F7:

ParameterDescriptionTypical SettingNotes
A1-02Control Mode Selection3“Vector control with PG”
F1-01Encoder Pulses per Revolutione.g., 1024 PPRMatch actual encoder
F1-03PG Input Type0Differential TTL input
E1-04Rotation Direction Logic0 or 1Depends on wiring
U1-05Monitor Speed FeedbackUsed for verification

Commissioning Steps

  1. Open-loop Test
    Run the inverter without enabling PG feedback. Verify that the motor runs smoothly and direction matches your system.
  2. Enable Closed-Loop Mode
    Set A1-02 = 3 and cycle the power. The inverter now reads encoder feedback. Observe that the motor starts softly and maintains constant speed.
  3. Zero-Servo or Position Hold
    For applications requiring shaft holding, fine-tune parameters F1-05 to F1-07.
  4. Verification
    Check parameter U1-05 to ensure displayed speed matches the actual RPM measured by a tachometer.

6. Practical Field Experience and Case Studies

Case 1: Speed Feedback Optimization

A 37 kW Varispeed F7 inverter driving a conveyor motor used a 1024 PPR encoder.
After replacing a damaged PG-A2 with an SI-P1 Ver 3.04, the system was configured with:

  • A1-02 = 3
  • F1-01 = 1024
  • F1-03 = 0

Result:
Acceleration response improved from 100 ms to 40 ms, and steady-state speed fluctuation dropped below 0.3%.
The SI-P1 performed identically to the original PG-A2.


Case 2: Direction Error due to Reversed Phases

In a hoisting control system, swapping A/B signal pairs caused the inverter to misinterpret rotation direction, leading to oscillation.
After interchanging the A and B channels, feedback direction was corrected, and stability restored.


Case 3: Noise Interference and Shielding

A 15 m unshielded encoder cable caused ±5% speed variation due to EMI.
Replacing it with twisted-pair shielded cable and grounding only at the inverter side reduced fluctuation to ±0.2%.
Proper shielding proved critical for feedback reliability.


7. Signal Verification and Maintenance

Regular inspection of the PG system is essential for long-term stability.

7.1 Oscilloscope Test

Check A/B waveforms at the PG card input:

  • Duty cycle ≈ 50%
  • Phase shift ≈ 90°
    Distorted or noisy waveforms indicate cable damage or grounding issues.

7.2 Feedback Speed Monitoring

Under no-load constant-speed operation, monitor U1-05.
If speed fluctuates, inspect PG connections, encoder bearings, and connector pins.

7.3 Cleaning and Care

The PG card contains sensitive CMOS components.
Avoid dust or moisture.
Clean contacts periodically with isopropyl alcohol and ensure firm seating in the CN5 slot.


8. Signal Mapping Comparison: SI-P1 vs PG-A2

FunctionSI-P1 PinPG-A2 PinRemark
+5 V Supply11Encoder Power
0 V Ground22Common Ground
A Signal33Differential +
/A Signal44Differential –
B Signal55Differential +
/B Signal66Differential –
Z Signal77Zero Pulse
/Z Signal88Complement Zero
FG ShieldFGFGCable Shield Ground

The one-to-one correspondence confirms that SI-P1 can replace PG-A2 without modification.


9. Engineering Discussion and Technical Insights

  1. Functional Equivalence
    The SI-P1 Ver 3.04 is a fully compatible PG-A2 card, supporting all F7 feedback control modes including vector, torque, and zero-servo functions.
  2. Signal Quality is Paramount
    Differential signal integrity and proper grounding are more critical than parameter tuning.
    Incorrect grounding can produce random “PG Loss” or “OV” faults.
  3. Parameter Matching
    Always set the correct encoder PPR (F1-01) and direction logic (E1-04) to avoid instability or reverse torque.
  4. Maintenance Importance
    Connector oxidation and vibration loosening are common causes of intermittent speed errors.
    Regular re-seating of the card ensures reliability.
  5. Cost-Effective Substitution
    For legacy F7/G7 systems, the SI-P1 serves as an excellent, low-cost replacement for discontinued PG-A2 cards without any firmware or wiring change.

10. Conclusion

The Yaskawa Varispeed F7 remains one of the most reliable inverter platforms in industrial automation.
As the key interface between the drive and the motor’s feedback device, the PG card is indispensable for achieving high-performance vector control.

Through detailed examination, this study confirms that SI-P1 Ver 3.04 is technically equivalent to the PG-A2 model.
It shares the same wiring, electrical characteristics, and parameter settings.
When properly connected and configured (A1-02 = 3), it enables full closed-loop operation with high accuracy and stability.

For field engineers, understanding this equivalence provides a major advantage—allowing quick replacement, reduced downtime, and seamless integration in maintenance or retrofit projects.


11. Summary of Best Practices

  • Always use shielded twisted-pair cable, one pair per differential channel.
  • Ground the shield at one end only (inverter side).
  • Verify A/B phase direction before enabling closed-loop mode.
  • Configure feedback parameters carefully according to the encoder specifications.
  • Periodically check the CN5 slot and card contacts for corrosion or dust.

By following these practices, the SI-P1 PG feedback system can deliver long-term precision and reliability comparable to servo-class control systems.


Author’s Note

This article is written as an original technical analysis for maintenance engineers, automation specialists, and industrial electronics technicians who maintain or retrofit Yaskawa Varispeed F7 inverters.
It integrates both manual specifications and real-world experience gathered from field repairs and performance testing.