<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>cpu card rating &#8211; longi</title>
	<atom:link href="https://www.longi.net/tag/cpu-card-rating/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.longi.net</link>
	<description>World of used  industrial control products</description>
	<lastBuildDate>Tue, 10 Sep 2024 03:49:33 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>
	<item>
		<title>Modifying Power Ratings for ABB ACS800 Series VFD Control Boards</title>
		<link>https://www.longi.net/modifying-power-ratings-for-abb-acs800-series-vfd-control-boards/</link>
		
		<dc:creator><![CDATA[baiyuzhan]]></dc:creator>
		<pubDate>Tue, 10 Sep 2024 03:49:18 +0000</pubDate>
				<category><![CDATA[ABB DRIVES]]></category>
		<category><![CDATA[7200 RDCU]]></category>
		<category><![CDATA[ABB VFD]]></category>
		<category><![CDATA[ACS800]]></category>
		<category><![CDATA[cpu card rating]]></category>
		<category><![CDATA[Modifying Power Ratings]]></category>
		<guid isPermaLink="false">https://www.longi.net/?p=3089</guid>

					<description><![CDATA[<p>Modifying the power ratings on ABB ACS800 series VFD (Variable Frequency Drive) control boards can be performed following a set of detailed steps, depending on the firmware version of the RDCU (Remote Digital Control Unit) board. This guide outlines the processes for both pre-version 7200 and post-version 7200 RDCU boards. Pre-Version 7200 RDCU Power Rating [&#8230;]</p>
<p>&lt;p&gt;The post <a rel="nofollow" href="https://www.longi.net/modifying-power-ratings-for-abb-acs800-series-vfd-control-boards/">Modifying Power Ratings for ABB ACS800 Series VFD Control Boards</a> first appeared on <a rel="nofollow" href="https://www.longi.net">longi</a>.&lt;/p&gt;</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Modifying the power ratings on ABB ACS800 series VFD (Variable Frequency Drive) control boards can be performed following a set of detailed steps, depending on the firmware version of the RDCU (Remote Digital Control Unit) board. This guide outlines the processes for both pre-version 7200 and post-version 7200 RDCU boards.</p>



<h3 class="wp-block-heading">Pre-Version 7200 RDCU Power Rating Modification Steps</h3>



<ol class="wp-block-list">
<li><strong>Enter 9903 and set to YES</strong>:
<ul class="wp-block-list">
<li>Access the control panel and navigate to parameter 9903.</li>



<li>Set the value to YES to enable modification mode.</li>
</ul>
</li>



<li><strong>Enter 1603 and set to 564</strong>:
<ul class="wp-block-list">
<li>Navigate to parameter 1603 and enter the passcode 564.</li>



<li>This unlocks access to parameter groups 112 and 190.</li>
</ul>
</li>



<li><strong>Select XXNONE in 11206</strong>:
<ul class="wp-block-list">
<li>Navigate to parameter 11206 and select XXNONE.</li>



<li>This prepares the board for power cycle.</li>
</ul>
</li>



<li><strong>Power Cycle</strong>:
<ul class="wp-block-list">
<li>Turn off the power to the RDCU board.</li>



<li>Wait a few seconds and then turn the power back on.</li>
</ul>
</li>



<li><strong>Re-enter 1603 and set to 564 (again)</strong>:
<ul class="wp-block-list">
<li>Repeat step 2 to ensure the passcode is active.</li>
</ul>
</li>



<li><strong>Select the Desired Power Rating in 11206</strong>:
<ul class="wp-block-list">
<li>Navigate to parameter 11206 again and select the desired power rating (e.g., 170-3).</li>
</ul>
</li>



<li><strong>Initialize Parameters</strong>:
<ul class="wp-block-list">
<li>Perform any necessary parameter initialization steps as recommended by the manufacturer&#8217;s guidelines.</li>
</ul>
</li>



<li><strong>Final Power Cycle</strong>:
<ul class="wp-block-list">
<li>Repeat the power cycle process to ensure the new settings take effect.</li>
</ul>
</li>
</ol>



<h3 class="wp-block-heading">Post-Version 7200 RDCU Power Rating Modification Steps</h3>



<ol class="wp-block-list">
<li><strong>Enter 9903 and set to YES</strong>:
<ul class="wp-block-list">
<li>Same as the pre-version 7200 steps.</li>
</ul>
</li>



<li><strong>Enter 1603 and set to 564</strong>:
<ul class="wp-block-list">
<li>Same as the pre-version 7200 steps.</li>
</ul>
</li>



<li><strong>Select the Desired Power Rating Directly in 11221</strong>:
<ul class="wp-block-list">
<li>Instead of using 11206, navigate to parameter 11221 and directly select the desired power rating (e.g., 11221 = sr170_3).</li>
</ul>
</li>



<li><strong>Re-enter 9903 and set to YES (optional)</strong>:
<ul class="wp-block-list">
<li>Depending on the specific firmware, this step may be optional but recommended for confirmation.</li>
</ul>
</li>



<li><strong>Power Cycle</strong>:
<ul class="wp-block-list">
<li>Turn off the power to the RDCU board and then turn it back on.</li>
</ul>
</li>
</ol>



<h3 class="wp-block-heading">Notes and Cautions</h3>



<ul class="wp-block-list">
<li><strong>Parameter Ranges</strong>: Note that parameters 11219 to 11223 represent different power ratings. Ensure you select the correct one for your application.</li>



<li><strong>Normal Usage Caution</strong>: Do not modify the settings on a normally operating VFD unless absolutely necessary, as it may result in the loss of important operational parameters.</li>



<li><strong>Firmware Differences</strong>: Always refer to the latest ABB documentation for your specific firmware version, as steps may vary slightly between versions.</li>



<li><strong>Parameter Unlocking</strong>: Remember that entering 564 in parameter 1603 unlocks advanced parameters, allowing for the modification of power ratings and other settings.</li>
</ul>



<p class="wp-block-paragraph">By following these steps carefully, you can safely modify the power ratings of ABB ACS800 series VFD control boards, ensuring optimal performance and compatibility</p>